TESTER UZ-L Onboard flight data recorder
|
FUNCTION:
Is used for flight data recording. On ground the information processed to estimate:
- piloting skills of crew
- technical condition of board systems
- reliability of the aircraft in service.
Completeness:
- Processing unit 1IM
- Flight recorder M2-T3
- Unit of installation of number of actuation 3ИМ
- Unit of recording amplifiers and reproducers 5ИМ
SPECIFICATIONS
- Quantity of measuring of continuously varying parameters 256 (512) times per second
- Quantity of inputs of continuously varying parameters 38
- Quantity of measuring of event signals 208 (416) times per second
- Quantity of inputs of single commands not less then 32
- Voltage from 18V up 31V
- Maximum consumed power 100W
- Defensive container of the magnetic recorder saves the information from:
- shock solitary 9800 m/s2
- temperature 1000° C within 15 minutes
- ocean water about 5 day
- extinguish ant fluids, kerosene about 2 day
- Mass of the set no more than 13,5 kg
|
|