Combined Cycle Plant on base GTU89-PT- 20, Power 60-120MW. Combined gas and steam energy-block is performanced on traditional plan. On the single frame the gas generator and the power turbine are mounted. Shaft of power turbine through the gas collector is joined with a generator alternating current.
The unit realizes a combined cycle (gas and steam). Steam is move in the flowing part of turbine. The block GTU is built by steam boiler is calculated on two level of pressure. High pressure ~ 90 kg/sm³ and temperature 600 0C for the steam turbine that are running jointly with the gas turbine. Steam of low pressure is use for cooling of the components flowing part the unit. Mixture of gas and steam is cool in steam boiler about 90-1000C and move into condenser and there is condense about 40-500C. Condensate then moves again in cycle.
Basic Technical Data
Output power, MW ................................ 60-120
Thermal efficiency, %................................. >52
Rotor speed, rpm¨¹ .................................. 3000
Type of fuel ............... natural gas
Heat flow (high pressure), kg/h................ 50.000
Temperature, °C ........................................ 530
Pressure, bar................................................ 85
Heat flow (low pressure), kg/h .................. 4.000
Temperature, °C......................................... 200
Pressure, bar ................................................ 6
Heat output, MW .......................................... 59
Overall life (Power turbine), hours ......... 100.000
Emission, NOx, mg/m³ ...............................
|