General technical requirements and characteristics: 1. Working medium ..... natural gas ace. to RF Industrial standard 08T.51.40- 83 2. Inlet pressure ..... 2,4- 3 mPa 3. Inlet temperature ..... 5 -20 ° C 4. Water inclusion ..... 10 mg/cub.m 5. Noncompressible compound content, H2S including ..... up to 10 mg/cub.m 6. Molecular weight .....17,4g/mol 7. Total flow rate ..... 65normal cub.m/h 8. Outlet gas parameters: Well head equipment pneumatic power units pressu ..... 2,4 - 3 mPa Measurement and control device gas pressure ..... 0,7 mPa Due point ..... -40 oCat3 mPa Row rate at 2,4 - 3 mPa ..... 26 normal cub. m/h Row rate at 0,7 mPa ..... 25 normal cub. m/h 9. All over sizes ..... 1800x1000x600 mm 10. Mass (no more than) ..... 200 kg 11. Climatic realization typeYI ace. to RF Stand. 15150-69; Gas preparation subunit is set for operation in medium climate region (II 5 ana. to RF Standard 15350-80) at environment temperature range -06 °C - +42'C 12. Electrical power ..... requirements 220 V 50 Hz AC 13. All electric power devic es are to be in explosion safe design mode and is to be used in explosion dangerous operating zones B-1 at mixture dangerous grade IIB, mixture group T3 ace. to RF Stand. 15150-72 . 14. Nominal power no more ..... 1 kW.